Showing results: 151 - 165 of 170 items found.
-
42-890-006 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-004 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-002 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-004 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-003 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-001 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-001 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-003 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-005 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-006 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-192-012 -
Pickering Interfaces Ltd.
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
150579-01 -
NI
96-Pin Male SCSI to 96-Pin Female SCSI Switch Cable, 1m (protected) - The SH96F-96M SwitchBlock SCSI Cable provides connectivity for SwitchBlock modules. You can connect these to the TBX-2809 Terminal Block, which exposes each channel of the switch module to screw terminals.
-
781420-00 -
NI
4-Slot PXI Carrier Module for SwitchBlock - The PXI‑2800 is a carrier module for SwitchBlock that can hold up to six SwitchBlock relay cards while occupying four PXI slots. By connecting multiple SwitchBlock relay cards through the carrier’s integrated analog bus, you can easily create large matrices with more than 2,000 crosspoints in four PXI slots and more than 8,000 crosspoints in a single PXI chassis.
-
40-855-222-M -
Pickering Interfaces Ltd.
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
40-792-701 -
Pickering Interfaces Ltd.
The 40-792/793 Daisy Chain Switching Module is designed for telecom test applications. It allows production or verification testing of SONET/SDH transmission multiplexers switching 2MBit/s or 1.5MBit/s data. Traffic is sequentially Daisy- Chained through all tributaries (or any selection of tributaries), modules can be cascaded to test any number of tributaries.